3 - Studio 12 Scan Control operating modes
On the Studio 12 Scan Control, the “traditional “ section, normally used for controlling dimmers
can be used in two operating modes:
- with two 12-channel presets with the possibility of mixing the two (double preset mode);
- with one 24-channel preset (single preset mode).
Changing from one operating mode to another is extremely easy, even if it’s not possible to chan-
ge accidentally.
When the console is switched on, the mode in which the console is being used appears on the
display for approximately 5 seconds:
or .
To change operating mode, with the console switched off, press the and
buttons and hold them down, then switch the console on.
The new operating mode will be shown on the display as already indicated.
When the console is switched on in “double preset” mode, the two LEDs of the but-
tons flash simultaneously, whereas in single mode they flash alternately.
In the scenes stored in the REGISTERS in “single preset” mode on 24 channels, once the opera-
ting mode has been changed to “double preset” (i.e. with 12 channels), only the first 12 channels
are output. The scenes aren’t lost however: when the operator returns to “single preset” mode,
the 24 channels are restored along with all their scenes.
When “single preset” mode is used, the buttons are used to switch the presets’
FLASH buttons from one 12-channel bank to the other: A for channels 1-12, B for channels 13-
24. This is very important, because the FLASH button’s LEDs are also used as channel level moni-
tors.
Buttons A and B also have to be used to remove the group from 1 to 12 and 13 to 24 from LINK
mode.
The preset’s general level is only regulated by fader A and the MANUAL PRESET and Master B
potentiometers aren’t enabled.
In “double preset” mode, it’s possible to mix presets A and B, either manually or automatically,
using MANUAL PRESET CROSS TIME (see chapter 4).
Studio 12 Scan Control consoles’ channels are set to operate with channels 1 - 24 as dimmer
controls.
Should another setting be required, check the functions of the DMX UNIT CONTROLS section,
which has powerful patching functions.