SGM Studio 12 User Manual Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
GB
appendice
page 31
I D F E
to access setting and the left-hand button to exit the function.
Once OK (right-hand SCROLL) has been pressed, the following menu appears:
. Use the CURSOR up/down
arrows to set the value and the right-hand SCROLL to confirm the choice and return to the pre-
vious menu.
In this case: .
These settings therefore indicate that the Remote Reset channel operates on channel 10 and runs
a reset when values of between 235 and 255 are sent.
Some fixtures require the action of a virtual reset, similar to that of cut-off switches after they trip:
before turning these switches on again, their protections must be reset. This is why a single value
is not given for this operation, but a range from a minimum to a maximum, outside of which the-
re’s no reset (Off), and therefore the value of real tripping is indicated (Off). All these operations
are carried out by the desk itself when the parameters are set and run in the aforementioned UTI-
LITIES.
Press the right-hand SCROLL to return to the creation menu now. Storage is automatic.
8.5.1.10 - Dip-switch configuration
This menu is used to enter the data that allow the Scan Control to show the exact configuration of
the dipswitch for addressing the units during unit assignment procedure (see 8.2). If the new unit
does not have a dipswitch, but a built-in microcomputer, these settings can be omitted. The fol-
lowing menu appears:
. Press the right-hand arrow
to access setting and the left-hand one to exit the function. Once OK (right-hand SCROLL) has
been pressed, the following menu appears:
. Use the CURSOR up/down
arrows to set the value, the left and right-hand ones to pass from parameter to parameter and the
right-hand SCROLL to confirm the choice and return to the previous menu. The number of swit-
ches (n.dip) which make up the dipswitch section indicates which type of component the fixture’s
manufacturer has used.
The dipswitch enters addresses in binary logic, summing all the values shown by the switches set
at ON: .
There are two ways of using this addressing system: the first uses a pure binary system, whe-
reas the second automatically adds a 1 to the address. We shall therefore indicate if the FIRST
CHANNEL has a value of 1 or 0. Addressing changes according to the two examples of fig. 1
1
2
4
8
16
32
64
128
256
1 2 3 4 5 6 7 8 9
ON
OFF
ENTER THE DIP-SWITCH CONFIGURATION
n.dip=[ 9] 1st channel= 0 ˛ ok->
Select feature to configure for esc<-
VICTORY TST --[DIP-SWITCH CONFIG.] ok->
RESET OFF ON ≥ LAMP OFF ON
[10] 234 255 ≥ -- --- --- ok->
RESET OFF ON ≥ LAMP OFF ON
[--] --- --- ≥ -- --- --- ok->